ID EN
Products

HVAC Systems for Sterile Rooms & Cleanrooms

We install and maintain HVAC systems that control temperature, humidity, filtration and air pressure in sterile rooms, including operating theater, cath lab and cytotoxic room HVAC for several regional hospitals in East Java.

Office in West Bandung · Serving all of Indonesia

Ducting and HVAC unit installation
Ducting and HVAC unit installation
HVAC

Heating, Ventilation & Air Conditioning

Our HVAC (Heating, Ventilation, and Air Conditioning) systems control temperature, humidity, filtration and air pressure in sterile rooms as one integrated system.

Main AHU functions
  1. Ventilation: brings in fresh air and removes stale air
  2. Filtration: removes dust, particles and contaminants
  3. Temperature conditioning: heats or cools the air
  4. Humidity control: adds or removes moisture
  5. Air distribution through the building via ducting
Air Handling Unit (AHU)
Air Handling Unit (AHU)
Modular AHU
Modular AHU

Air Handling Unit (AHU)

The HVAC unit that conditions and circulates air as part of a building's heating, cooling and ventilation.

Specifications
  • Material: insulated sandwich panel
  • Cooling capacity: 100,000–150,000 BTU/h (as required)
  • Air flow: 1500–2500 CFM
  • Air static: 1000–1500 Pa
  • Custom unit, electric heater
  • Pre filter & medium filter, UV lamp sterilizer
Exhaust Fan Unit (EFU)
Exhaust Fan Unit (EFU)

Exhaust Fan Unit (EFU)

Extracts indoor air and discharges it outside to maintain air quality. In negative-pressure operating rooms, the EFU exhausts air through filtration so diseases and viruses do not spread.

Specifications
  • Material: insulated sandwich panel
  • Air flow: 1500–2500 CFM
  • Air static: 1000–1500 Pa
  • HEPA filter, 99.9% efficiency
  • UV lamp sterilizer
HEPA filters
HEPA filters
Pre filters and medium filters
Pre filters and medium filters

Air Filter & HEPA Filter

Key components for air quality in hospitals, laboratories, production rooms and industry.

Specifications
  • Pre filter: large particles such as dust and fibers
  • Medium filter: medium particles, for production rooms, labs and hospitals
  • HEPA filter: microscopic particles including allergens and bacteria
  • Carbon filter: odors, gases and VOCs
  • Electrostatic filter: smoke and pollen
Operating theater HMI monitoring screens
Operating theater HMI monitoring screens

HMI Monitoring Control

One-touch control and monitoring of the operating theater. Features are tailored to the theater type.

Specifications
  • 10–22 inch touchscreen
  • Frame stainless steel SUS 304
  • Power 220 VAC 50/60 Hz
  • HVAC control, room control, event alarm, data logger, medical gas alarm, entertainment (music & video)
Ducting installation
Ducting installation

Ducting Installation

Air duct installation using tested, high-quality products.

Specifications
  • Pre-insulated aluminium duct, green product non-CFC
  • Thickness 20 mm, density 71.49 kg/m³
  • Working temperature -60 to +80 °C, humidity 0–100%
  • Max. pressure 2,000 Pa
Connecting refrigerant piping to an outdoor unit
Connecting refrigerant piping to an outdoor unit

Pipe Installation

Gas and liquid piping with quality insulation.

Specifications
  • High-pressure pipe 5/8" with insulation
  • Low-pressure pipe 1 1/8" with insulation
  • Drain pipe 3/4" & accessories
Outdoor unit
Outdoor unit

Outdoor Air Conditioning

Outdoor units that drive the AHU cooling coil, sized to the project, from well-known brands such as Daikin, Hisense and others.

Laminar air flow ceiling
Laminar air flow ceiling

Laminar Air Flow

Laminar flow technology for a contaminant-free environment, with medical-grade HEPA filters of 99.9% efficiency (H13, per EN 1822).

Specifications
  • Homogeneous membrane layer
  • Perforated stainless steel
Integrated control panel
Integrated control panel
Ducted coil unit
Ducted coil unit

Other Components

Manual & motorized air volume dampers (stainless steel / powder-coated galvanized), perforated SUS 304 return air grilles, and an integrated control panel (800 × 600 × 250 mm, indoor, powder-coated) with sensors and a program controller for integrated automatic control.

References

Related Projects

Operating theater AHU maintenancePhoto coming soon
West Bandung

RSUD Cililin

Operating theater AHU maintenance

ICU HVAC maintenancePhoto coming soon
West Bandung

RSUD Cililin

ICU HVAC maintenance

Radiology HVAC maintenancePhoto coming soon
West Bandung

RSUD Cililin

Radiology HVAC maintenance

Cytotoxic room HVAC supplyPhoto coming soon
Blitar, East Java

RSUD Mardi Waluyo

Cytotoxic room HVAC supply

Operating theater HVAC for RSUD Karsa Husada BatuPhoto coming soon
Batu, East Java

PT. Interindo Tri Sinergy Utama

Operating theater HVAC for RSUD Karsa Husada Batu

Operating theater HVAC for RSUD dr. Koesma TubanPhoto coming soon
Tuban, East Java

PT. Interindo Tri Sinergy Utama

Operating theater HVAC for RSUD dr. Koesma Tuban

Cath lab HVAC for RSUD dr. Koesma TubanPhoto coming soon
Tuban, East Java

PT. Interindo Tri Sinergy Utama

Cath lab HVAC for RSUD dr. Koesma Tuban

Why us

Why Choose PT. Mahira Buana Karya?

Experienced Expert Team

Backed by an expert team with broad cleanroom experience, covering integrated design, installation and maintenance.

Structured Project Management

Well-structured, well-organized project management to ensure on-time and on-budget completion.

24/7 Support

24/7 customer support and fast, responsive and effective after-sales service to ensure customer satisfaction.

Ready to build a sterile room that meets standards?

Discuss your cleanroom, operating theater or HVAC needs with our team.

Contact

Contact Us

Tell us about your project. Our team will get back to you, or chat with us directly on WhatsApp.

Inquiry form

Your details are only used to follow up on this inquiry.

WhatsApp